• 3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
  • 3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
  • 3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
  • 3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
  • 3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
  • 3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply

3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply

Phase: Single Phase
Type: On-line
Protection: Overvoltage
Application: Communication
Classification: Lighting/Power
Standby Time: Standard Machine

Tedarikçi ile İletişime Geçin

Altın Üye Fiyat 2024

Doğrulanmış işletme lisanslarına sahip tedarikçiler

Guangdong, Çin
Yüksek Tekrarlı Alıcıların Seçimi
Alıcıların %50'sinden fazlası sürekli olarak tedarikçiyi seçiyor
Fortune 500 ile işbirliği yapıldı
Bu tedarikçi Fortune 500 şirketleriyle işbirliği yaptı
Doğrulanmış tüm güç etiketlerini (20) görmek için
  • Genel bakış
  • Product Description
  • Detailed Photos
  • Product Parameters
Genel bakış

Temel bilgiler.

Hayır. Modeli.
UPS 3KVA 2700W 220V
Standby UPS
Square Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
voltaj
1 kva - 10 kva
kapasite
60% 90% of Rated Power
özelleştirme
OEM Add Your Logo Brand
dalga formu
saf sinüs dalgası online ups
Taşıma Paketi
Carton
Teknik Özelikler
4.6 kg
Ticari Marka
OEM
Menşei
Shenzhen China
HS Kodu
8504402000

Ürün Açıklaması

 

Product Description

 

Provide maintenance bypass

The DSP technology guarantees a high-performance level

Output power factor of 1.0/0.6/0.8/0.9

Power supply walk-in function

With a power factor correction

The 50 Hz/60Hz frequency converter mode

Energy-saving working mode(ECO)

Emergency shutdown off(EPO)

SNMP +USB +RS-232 Multiple communications

Three-stage charging design to optimize the battery performance

Adjustable battery number, suitable for long time operation

Support for shared battery packs

Support generator
 

Detailed Photos


3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply

3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply



3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply
3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply

 

Product Parameters

 

 
 
Item Model      
Capacity VA / Watts 1KVA / 0.8KW or 0.9KW 2KVA / 1.6KW or 1.8KW 3KVA / 2.4KW or 2.7KW
input Normal voltage 220VAC or 110VAC
Turn on Voltage range (115+-5~300+-5)VAC or ( 60+-5-138+-5)VAC
Frequency range 40~60Hz(adjustable) 40~60Hz(adjustable) 40~60Hz(adjustable)
Input power factor >0.99(220VAC,full R load)
Generator Support generator input(Generator rating2*UPS rating )
line low loss/comeback 220VAC:(110±5)VAC/(195±5)VAC when Load55%,   110VAC:(60±3)VAC/(65±3)VAC when load40%
220VAC:(130±5)VAC/(195±5)VAC when56%< Load65%,   110VAC:(60±3)VAC/(75±3)VAC when40%< load50%
220VAC:(150±5)VAC/(195±5)VAC when66%< Load70%,   110VAC:(70±3)VAC/(75±3)VAC when50%< load60%
220VAC:(160±5)VAC/(195±5)VAC when71%< Load90%,   110VAC:(70±3)VAC/(85±3)VAC when60%< load70%
220VAC:(185±5)VAC/(195±5)VAC when Load>90%,   110VAC:(90±3)VAC/(95±3)VAC when load>70%
Output Voltage range 200VAC/208VAC/220VAC/230VAC/240VAC/110VAC/120VAC, need confirm before order
Frequency range 50Hz or 60HZ+-0.2Hz(Battery mode)
Wave form Pure Sine Wave
Transfer time 0 ms, Between Line mode and Bat mode
Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode
Distortion 4%,Full linear load 4%,Full linear load 4%,Full linear load
Degree of distortion 7%,Full nonlinear  load 7%,Full nonlinear  load 7%,Full nonlinear  load
Overload capacity <105% warning only, <125% 30s ; <150% 20s,>150%, 300MS to bypass
Load peak ratio 3:1(max)
Standard Modes XG1-3K Battery Type Maintenance free valve regulated lead acid (VRLA) battery
Battery voltage 24VDC or 36VDC 48VDC or 72VDC 72VDC or 96VDC
Internal Battery 2*7AH(9AH) or 3*7AH 4*7AH(9AH) or 6*7AH or 8*7AH 6*7AH(9AH) or 8*7AH
Recharge time 5 hours to 90%capacity
Charge Current 1A 1A 1A
Long backup ModeXG1-3KL Battery bank 36VDC, External 72VDC,External 96VDC,External
Charge Current 5Amp,Max 7Amp 5Amp,Max 7Amp 5Amp,Max 7Amp
Display LED Mode Load level / Battery level / Battery mode / Line mode / Inverter , Bypass ,Over load , Fault
LCD Mode input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp.LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypss
Audible Alarm Battery Mode Beeping every 4 seconds (re-settable) and every second when battery low
Overload Beeping twice every second
Fault Beeping Continuously
Bettery low/charger fault Beeping every 1 second
Bypass mode Beeping every 2 min
L/N inverse Beeping every 2 min
Communications RS-232/USB Interface With monitoring software
Working Environment Surge protection RJ-45  I/O port available for network or Fax/Modem
Working temperature - 20ºC~40ºC
Humidity 0-95% non-condensing
Product size WxDxH (mm) 350*145*230(H) 430*190*328(H) 430*190*328(H)
PCS/CTN   2 1 1
CTN size WxDxH (mm) 495*470*340(H) 570*305*450 (H) 570*305*450 (H)
N/W, CTN  XG1-3K Kg 19/23  (base on 7AH) 19/23/28 (base on 7AH) 24/28 (base on 7AH)
N/W, CTN  XG1-3KL   12 12 12
G/W, CTN XG1-3K Kg 21/25 21/25/30 25/30
G/W, CTN XG1-3KL   15 14 14
REMARK XG*K --- Standard Type Internal battery, XG*KL      Long Time Type,External battery
 

Sorgunuzu doğrudan bu sağlayıcıya gönderin

*İtibaren:
*Şuradan:
*Mesaj:

Lütfen 20 ila 4000 karakter arasında girin.

Aradığınız şey bu değil? Satın Alma talebini Şimdi Yayınla

Kategoriye Göre Benzer Ürünleri Bulun

Tedarikçi Ana Sayfası Ürünler Çevrimiçi UPS GÜCÜ (Yüksek Frekans) 3kVA 2700W 220V PF0.9 Online UPS Ecologic Battery Backup Surge Protector Uninterruptible Power Supply

Bunları Da Beğenebilirsiniz

Tedarikçi ile İletişime Geçin

Altın Üye Fiyat 2024

Doğrulanmış işletme lisanslarına sahip tedarikçiler

Üretici/Fabrika
Çalışan Sayısı
6
Kuruluş Yılı
2023-11-22