506 W, 30 V 5,6 A, 5,6 V 8 A Özelleştirilmiş Güç Kaynağı

Output Type: Dual
Warranty: 2 Years
Output Power: 506W
Input Voltage: 100-240VAC
Certification: CE, RoHS, CCC, CB
Brand: Goldpower

Tedarikçi ile İletişime Geçin

Elmas Üye Fiyat 2007

Doğrulanmış işletme lisanslarına sahip tedarikçiler

Üretici/Fabrika, Ticari Şirket

Temel bilgiler.

Hayır. Modeli.
506W, PPC32 A013
Taşıma Paketi
Carton
Ticari Marka
Goldpower
Menşei
China
HS Kodu
8504401400

Ürün Açıklaması

Welcome to use PPC32 A013 customized power supply from Goldpower. The power supply is with wide input voltage range and normally works with 90V~286Vac input. The input voltage, input power, output voltage can be reported to the software, and the +30V,+5.6V output voltage are adjustable. Protections against output short-circuit, over-current, over-voltage, intput over/under-voltage are functional. The power supply is designed strictly in accordance with the safety regulations, which conforms to the safety standards and requirements of information technological equipment. The power supply has many characteristics, which makes it applicable with wide application field!
1. Specification
Operation environment
 Parameter Min. Typ. Max. Unit Remark
Operation temperature range -40 25 80 ºC  
Nominal operation temperature range -40 25 70 ºC Within safety certification range.
Relative humidity 5   95 % Long-term operation without condensing.
Altitude 0   5000 m For operation above 3000m, the max. operation environment temperature is derated by 1ºC per 100m.
Working hours 24 hours everyday.
Cooling Nature cooling.  Components with heating power more than 0.5 W shall be installed closely to the internal case for cooling.
           
 
Storage environment requirement
 Parameter Min. Typ. Max. Unit Remark
Storage temperature range -50 25 85 ºC  
Relative humidity 5   95 %  
Altitude     5000 m  
Max. rate of temperature variation     5 ºC/min  
 
Input
 Parameter Min. Typ. Max. Unit Remark
Nominal input voltage range 100 110/220 240 Vac Safety Certified in the range of Nameplate nominal voltage range.
Input operation voltage range 90 110/220 286 Vac  
130 200/300 380 Vdc  
Max. input voltage 315     Vac Under this input voltage, inoperation without damage is allowed,.
Rated input voltage   110/220   Vac  
AC input frequency 45 50/60 66 Hz  
Power factor 0.95       Test with rated input & typical load .
Input inrush current       A Normal temperature, test with rated input & typical load output, cold-start.
Comply with ETSI300132-3 Standard.
Double L wire input There shall be fuse with L/N, inverse-prevention function is functional at high voltage DC input, the power supply can work normally without distinguishing for positive and negative polarity.
Grounding +30V,+5.6V outputs sharing the same grounding.
Output
 Parameter Min. Typ. Max. Unit Remark
Rated output voltage Output 1   30   Vdc  
Output 2   5.6  
Output voltage adjustable range +30V 20   31.5 Vdc  
+5.6V        
Output voltage range +30V 29.1 30 30.9 V  
+5.6V 5.48 5.6 5.72
Output current range +30V 0 12 15 A  
+5.6V 5 8 10
Vp-p noise voltage +30V     200 mV 20MHz bandwidth limitation, with10uF/50V,0.1uF/50V capacitors.
 
+5.6V     100
           
Output voltage setting value -53.5 -54 -54.5 V Rated input,Rated output
Rated output current 0 15   A 90Vin154 derating to 10A
Output rated power   810   W 90Vin154 derating to 540W
Load regulation     ±3 %  
Voltage regulation     ±2 %  
Stabilized voltage precision     ±5 %  
Overall efficiency 91 91.5   % Rated 220V input, typical load output, with environment temperature 25ºC.
87     Rated 110V input, typical load output, with environment temperature 25ºC.
Temperature coefficient     ±0.02 %/ºC  
Output power   404.8 506 W  
Dynamic response recovery time +30V     200 µS Load variation: 25%~50%~25% or 50%~75%~50%,
Load changing rate is 0.1A/uS
+5.6V     200
Dynamic response overshoot +30V     ±5 % Load variation: 25%~50%~25% or 50%~75%~50%,
Load changing rate is 0.1A/uS
    ±10   Large dynamic test, referring to Remark 1.
+5.6V     ±5   Load variation: 25%~50%~25% or 50%~75%~50%,
Load changing rate is 0.1A/uS
Startup output delay     4 S  
Startup/shutdown overshoot     ±5 %  
Output voltage rise time +30V 1   200 mS  
+5.6V 1   20
Capacitive load +30V     1500 uF/A The output voltage rise from 10% to 90%, rated load with the output waveform rising monotonically
+5.6V     4000
Powerdown delay function Related to DIP function.
Output ground-sharing Two outputs sharing the same grounding.
Remark :Test with 154VVin290V,output rated 54V/15A,and 90VVin154V,output rated 54V/10A.
                     
Remark 1: Requirements for Large dynamic  test:
  1. Temperature range:High temperature of +80ºC, normal temperature, low temperature of -40ºC;
  2. Cycle: 5ms,Duty cycle: 0.743;
  3. Test method:0A18A0A,0A18A0A;Load variation rate:0.1A/uS,Test with max. load with +5.6V.
  4. Standard: The circuit shall be stable without damage with the power supply, the dynamic response overshoot shall not exceed 10%.
 
 Protection
 Parameter Min. Typ. Max. Unit Remark
Input over-voltage protection point 300     V Auto recoverable.
There shall be no protection within 400Vdc at high DC input.
Test with typical testing conditions.

 
Input over-voltage recovery point 286     V
Input over-voltage protection hystersis 3     V
Input under-voltage protection point     87 V Auto recoverable.
There shall be no protection for over 130Vdc  at high DC input.

 
Input under-voltage recovery point     90 V
Input under-voltage protection hystersis 3      
Output over-voltage protection +30V 35   45 V  
+5.6V      
Output over-circuit protection +30V 16   30 A  
+5.6V 11   30
Short-circuit protection       A Long term short-circuit endurable. There shall be no damage.
Auto recoverable after short-circuit be removed.
Over-temperature protection       ºC The power supply is equiped with over-temperature protection function and no damage @ protection. Auto recoverable when temperature fall to environment temperature range.The power supply can operate properly in the range of specified temperature without over-temperature protection.Over-temperature protection hystersis is more than3ºC.The temperature of components will not exceed the max. operation temperature before protection.
             


1. Specification

 
EMC Specification Requirement
Item  Specification requirement Standard
ESD Air discharge: ±4KV, ±15KV
Contact discharge: ±8KV   
EN61000-4-2 (Criterion A)
 RS Testing range:80M~6G;
Testing intensity:
800MHz~960M: 10V/M
1.4GHz~2.7GHz: 10V/M
Others range: 3V/m
Amplitude modulation: 80%AM(1kHz)  
EN61000-4-3 (Criterion A)
CS Testing frequency: 0.15 MH~80 MHz,
Testing intensity: 10V,
Amplitude modulation: 80%AM(1kHz)
EN61000-4-6 (Criterion A)
EFT/B ±4KV    EN61000-4-4 (Criterion B)
SURGE :line-line: ±4kV(internal resistance2Ω);
line-ground: ±6kV(internal resistance12Ω) 
EN61000-4-5 (Criterion B)
Lightning current line-line/line-ground: 5kA
test with 8/20 μs waveform.
YD/T 1235.2-2002-I
8/20 μs waveform(Criterion C)
DIP Dip to 0%Ut, duration 10ms  
Dip to 0%Ut, duration 20ms  Ut= 220Vac, typical load condition: EN61000-4-11(Criterion B)
Dip to 70%Ut,duration 500ms Ut= 220Vac, typical load condition: EN61000-4-11(Criterion B)
Dip to 0%Ut,duration 5000ms Ut= 220Vac, typical load condition: EN61000-4-11(Criterion C)
Dip to 0%Ut, duration 200ms  Criterion B
CE CLASS B, with 2.3dB margin
CLASS B with system tested.
EN55022.
 
RE CLASS A, with 3.6dB margin
CLASS B with system tested.
Current harmonics Meet the requirement for CLASS A products IEC61000-3-4
Voltage fluctuation and flicker Pst1.0; P1t 0.65; dc3%; dmax4%;
d(t) 3% when duration>200mS
IEC61000-3-3

Criterion Standard:
Criterion A(for continuity)
  1. DC output range shall be comply with normal working condition during interference.
  2. No alarms, error alarm indication(power failure,protection fault) ,error indication during operation during or after interference.
Criterion B(for transience)
  1. DC output voltage variation during testing shall make no difference to the Crition B:
  2. Peaks during interference shall not be considered;
  3. No alarms,error alarm indication(power failure,protection fault) or error indication during operation during/after interference;
  4. Auto recoverable to normal performance after interference finished.
CriterionC(for interruption)
Temporary non-performance is allowed, but the power supply shall recover automatically or manually, as well as by operation.
Powerdown during the test is allowed, but the power supply shall recover automatically.
CriterionR(for susceptibility)
No damage or other interference during testing(eg, software damage or improper operation of fault protection unit). The power supply shall operate properly within specified range after transient electromagnetic(not required during testing). The interference may result in actions of fuse or other device, and shall be replaced or reset before recovering to normal operation.

Remark 1: Single power supply shall pass the test with pure resistive load in the system chassis, the test results shall meet the laboratory margin requirement, 6 db margin is required for tests outside our laboratory.

Remark 2: EMC Requirement for high voltage DC input: Test with rated input voltage 300 Vdc; Test items: all items included except for the DIP, current harmonics and the voltage fluctuation & flicker; RE and CE index be widened with 20 db, and meet the margin requirement of Remark 3.
1. Specification
Others
Item Technical requirement
Random vibration Frequency  Acceleration spectral density
5~20Hz: 1.0m2/s3;
20~200Hz: -3dB;
Totall root mean square acceleration: 0.781Grms; test directions:3 axes. Duration:30min per axe.
Shock Waveform : half sine-wave; peak acceleration:180m/s2; pulse width :6ms;
test directions:6; 3times per direction.
Collision Waveform: half sine-wave; peak acceleration:180m/s2; pulse width :6ms; direction:6 directions; 100times per direction.
Drop Weight15kg   height:100cm
Drop at 1 angle, 3 edges and 6 surfaces:
1 angle: The weakest angle shall be selected for drop test, otherwise, angle 2-3-5
3 edges: those intersect at above angle
6 surfaces: External surfaces of packaged unit,
1 time per surface.
Reliability ( calculated) 120,000 Hours
Acoustic noise 50dB
Odor No peculiar and deleterious odor
moisture proof GB/T2423.4-1993 ,24~45ºC,95%RH,48h
Mould proof GB/T2423.16-1999  CALLS 2
Fog proof GB/T2423.17-1999  96h
Low pressure test 5000m
 
Safety and Insulation Rating
Item Requirement Remark
Insulation voltage Input -output:3000Vac/10mA/60S No flashover or breakdown
 
Input -ground:1500Vac/10mA/60S
Output -ground: 500Vdc/10mA/60S
Contact current( PE) <3.5mA 264V input, 60Hz.
Contact current( output) <0.25mA
Grounding impedance <0.1  
Insulation resistance Under normal atmospheric pressure, relative humidity: 90%; Testing voltage: 500v DC; 
The insulation resistance of AC&DC(rectifer)-ground,and AC-DC shall not be less than 2MΩ.
     



2. Remote Signalling / Remote Control

 
Remote Signalling
Item Signal name Requirement Remark
Input powerdown alarm signal Vin_Down_ALM   Signal requirements: OC gate output, low level is normal (less than 0.3 V), floated or high level alarm (pull up the signal inside the main control module).  The absorb current shall not be  less than 5 mA.
Temperature detection   Error ≤±5ºC( Remark 1) I2C protocol adpted.
The signal level is 3.3 V, maximum rate is 100k.
Address: 0 b1011000x, X for read/write.
Input voltage detection   Error ≤±5%
Input power detection   Error ≤±10%
( Test with typical load condition)
Output voltage detection   Error ≤±5%

Remark 1: The location of the temperature sensor is not required,it can be placed in the specified area in structure drawing or inside the power supply.

 
Remote Control Function
Item Requirement Remark
+30V voltage regulating 30V output by default when there's no I2C voltage regulating signal Voltage regulating & output shutoff are conducted through I2C protocol.
Output shutoff control Anyone of 1-2 output or all outputs can be shutoff by the upper PC through the I2C, the power supply automatically return to normal output (the other output can be shutoff evenif one output be shutoff) for 1 ~ 5 s after the shutoff.
To avoid mistaken shutoff, the power supply will execute the shutoff commands after receicing shutoff commands for 3 times in 3s.


 

Sorgunuzu doğrudan bu sağlayıcıya gönderin

*İtibaren:
*Şuradan:
*Mesaj:

Lütfen 20 ila 4000 karakter arasında girin.

Aradığınız şey bu değil? Satın Alma talebini Şimdi Yayınla