• Soğutma Klima Elektrikli Motorlu Bilyalı Vana Çalıştırma1
  • Soğutma Klima Elektrikli Motorlu Bilyalı Vana Çalıştırma1

Soğutma Klima Elektrikli Motorlu Bilyalı Vana Çalıştırma1

Media: Oil
Material: Brass
Connection Form: Welding
Driving Mode: Electric
Channel: Straight Through Type
Structure: Fixed Ball Valve

Tedarikçi ile İletişime Geçin

Elmas Üye Fiyat 2021

Doğrulanmış işletme lisanslarına sahip tedarikçiler

Sınıflandırma: 4.7/5
Ticari Şirket
  • Genel bakış
  • Product Description
  • Packaging & Shipping
  • Company Profile
  • Our Advantages
  • FAQ
Genel bakış

Temel bilgiler.

Hayır. Modeli.
MB
Function
Bypass-Valve
Temperature
Low Temperature
Application
Industrial Usage, Water Industrial Usage, Household Usage
Taşıma Paketi
Box
Teknik Özelikler
1/4-3 1/8
Ticari Marka
N/A
Menşei
Zhejiang
Üretim Kapasitesi
30000

Ürün Açıklaması

Product Description
Refrigeration Air Conditioner Electric Motorized Ball Valve Fit for Actuator1

      Refrigeration Air Conditioner Electric Motorized Ball Valve Fit for Actuator

  • Design Pressure (DP) / Maximum abnormal pressure (MAP): Up to 775 psig, 53 bar
  • Power Supply: 24 VAC
  • Actuator Ambient Temperature: -22°F to 130°F, -30°C to 54°C
  • Valve Refrigerant Temperature: -40°F to 300°F, -40°C to 149°C
  • Full shutoff capability
  • Gradual Open/close stops line hammer
  • Remote operating capability
  • Removable actuator for quick change replacement
  • Manual override and valve positioning
  • Electronic overload protection

 

 

A sight glass is a transparent glass tube or window installed in a tank or boiler system that allows an observer to view what is happening inside the system.

The refrigerant sight glass is normally located anywhere liquid flow exists and anywhere it can serve a purpose. When it is installed just prior to the expansion device, the technician can be assured that a solid column of liquid is reaching the device. When it is installed at the condensing unit, it can help with troubleshooting.

Sight glasses come in two basic styles: plain and with a moisture indicator. The plain sight glass is used to observe the refrigerant as it moves along the line. The sight glass with a moisture indicator can tell what the moisture content is in the system. It has a small element in it that changes color when moisture is present.

What you see in the sight glass can help you diagnose system malfunctions. It is strongly suggested that you do not use the sight glass as the only means of diagnosis. Also, do not use the sight glass to diagnose R134a systems.

If the sight glass is clear, one of three conditions can exist: the system is completely empty, the system is full, or the system is overcharged. If there is foam, the charge is low, but if there are only a couple of bubbles, it is probably Ok. few bubbles when the compressor cycles on is normal. Oil streaks in the sight glass usually indicate a low charge and that the compressor is pumping oil from its sump. If the sight glass is cloudy, the desiccant bag has probably burst.

If an R134a system has a sight glass, do not use it or try to perform diagnosis, as it is normal to observe bubbles in this type of system.

Packaging & Shipping

Refrigeration Air Conditioner Electric Motorized Ball Valve Fit for Actuator1

Company Profile

Refrigeration Air Conditioner Electric Motorized Ball Valve Fit for Actuator1

Our Advantages

Refrigeration Air Conditioner Electric Motorized Ball Valve Fit for Actuator1

FAQ

Refrigeration Air Conditioner Electric Motorized Ball Valve Fit for Actuator1

Sorgunuzu doğrudan bu sağlayıcıya gönderin

*İtibaren:
*Şuradan:
*Mesaj:

Lütfen 20 ila 4000 karakter arasında girin.

Aradığınız şey bu değil? Satın Alma talebini Şimdi Yayınla