MODEL | ELG-100-24A | ELG-100-36A | ELG-100-42A | ELG-100-48A | ELG-100-54A |
OUTPUT | DC VOLTAGE | 24V | 36V | 42V | 48V | 54V |
CONSTANT CURRENT REGION | 12 ~ 24V | 18 ~ 36V | 21 ~ 42V | 24 ~ 48V | 27 ~ 54V |
RATED CURRENT | 4.0A | 2.66A | 2.28A | 2A | 1.78A |
RATED POWER | 200VAC ~ 305VAC |
96W | 95.76W | 95.76W | 96W | 96.12W |
100VAC ~ 180VAC |
70W | 70W | 70W | 70W | 70W |
RIPPLE & NOISE | 200mVp-p | 250mVp-p | 250mVp-p | 300mVp-p | 350mVp-p |
VOLTAGE ADJ. RANGE | Adjustable for A-Type only (via the built-in potentiometer) |
21.6 ~ 26.4V | 32.4 ~ 39.6V | 37.8 ~ 46.2V | 43.2 ~ 52.8V | 48.6 ~ 59.4V |
CURRENT ADJ. RANGE | Adjustable for A-Type only (via the built-in potentiometer) |
2 ~ 4A | 1.33 ~ 2.66A | 1.14 ~ 2.28A | 1 ~ 2A | 0.89 ~ 1.78A |
VOLTAGE TOLERANCE | ±3.0% | ±2.5% | ±2.5% | ±2.0% | ±2.0% |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
LOAD REGULATION | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% |
SETUP, RISE TIME | 1000ms, 80ms/115VAC 500ms, 100ms/230VAC |
HOLD UP TIME | 15ms/115VAC 10ms/230VAC |
INPUT | VOLTAGE RANGE | 100 ~ 305VAC 142 ~ 431VDC |
FREQUENCY RANGE | 47~63Hz |
POWER FACTOR | PF≥0.97/115VAC, PF≥0.95/230VAC, PF≥0.92/277VAC@full load |
TOTAL HARMONIC DISTORTION | THD< 20%(@load≥50%/115VC; @load≥60%/230VAC; @load≥75%/277VAC) |
EFFICIENCY | 88% | 89% | 90% | 90% | 91% |
AC CURRENT | 1.1A / 115VAC 0.6A / 230VAC 0.5A/277VAC |
INRUSH CURRENT | COLD START 60A(twidth=850μs measured at 50% Ipeak) at 230VAC |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC |
LEAKAGE CURRENT | <0.75mA / 277VAC |
PROTECTION | OVER CURRENT | 95 ~ 108% |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE | 28 ~ 34V | 41 ~ 48V | 47 ~ 54V | 54 ~ 62V | 62 ~ 72V |
Protection type : Shut down o/p voltage, re-power on to recovery |
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recovery |
ENVIRONMENT | WORKING TEMP. | Tcase=-40 ~ +90°C(Refer to "Derating Curve") |
MAX. CASE TEMP. | Tcase=+90°C |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40 ~ +80°C,10~95% RH |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 60°C) |
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
SAFETY & EMC | SAFETY STANDARDS | U8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.1, GB19510.14; IP65 or IP67 approved |
DALI STANDARDS | Compliance to IEC62386-101, 102, 207 for DA-Type only |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH |
EMC EMISSION | Compliance to EN55015,EN61000-3-2 Class C (@load≥60%); EN61000-3-3;GB17743, GB17625.1 |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV) |
OTHERS | MTBF | 282.9Khrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 199*63*35.5mm (L*W*H) |
PACKING | 0.75kg; 16pcs/13kg/0.72CUFT |