• Industrial Dry Cooler V Shapeddry Coolers
  • Industrial Dry Cooler V Shapeddry Coolers
  • Industrial Dry Cooler V Shapeddry Coolers
  • Industrial Dry Cooler V Shapeddry Coolers
  • Industrial Dry Cooler V Shapeddry Coolers
  • Industrial Dry Cooler V Shapeddry Coolers

Industrial Dry Cooler V Shapeddry Coolers

Condensation Forms: Air-Cooled
Refrigerant: CF2Cl2
Type: Air Cooled Condenser
Material: Zinc
Structural Form: Horizontal
Heat Transfer Mode: Regenerative

Tedarikçi ile İletişime Geçin

Elmas Üye Fiyat 2010

Doğrulanmış işletme lisanslarına sahip tedarikçiler

Üretici/Fabrika

Temel bilgiler.

Hayır. Modeli.
SHSL-D2-601-14X630F26
Form
Sheet
Application Field
Automotive Industry
Certification
RoHS, ISO
Condition
New
ürün adı
endüstriyel kuru soğutucu v mil kuru soğutucular
soğutma kapasitesi
294 kw
su akışı
60 l/sn
fan miktarı
14 adet
güç kaynağı
400 v - 3 ph - 50 hz
toplam motor gücü
38,5 kw
giriş/çıkış bağlantısı
dn125
giriş havası sıcaklığı
20 derece c
giriş/çıkış suyu sıcaklığı
35/25 derece c
Taşıma Paketi
Wrap Film/Pallet
Teknik Özelikler
refrigerant unit
Ticari Marka
VENTTK
Menşei
China
HS Kodu
8415901000
Üretim Kapasitesi
100units/Month

Ürün Açıklaması

Industrial dry cooler V shaped Dry Coolers 
Dry Coolers are widely used in refrigeration, air-conditioning, food processing, heating plants and power plants.

General productions:
  1. Suitable environment
  2. Dry Cooler series:D1 and D2 series.
  3. Environment temperature:  35ºC.
  4. Air does not contain chemical substances, corrosive gasses and dust-free;
  5. Please specify requirements for explosion-proof upon order
  6. Design Conditions:   Design pressure 2.0MPa; Test pressure 2.5MPa                
  7. Medium: WATER    
Working conditions:
Environment Specifications
Ambient Temperature 35ºC,                                  Inlet Temperature 48 ºC,Outlet Temperature 39 ºC     D4 Series
 
Details:
Sign Name Function
A Stand Fix equipment
B MetalSheet Casing Galvanized Steel Coated Casing
C Cooling Coil Al Fin and Copper Tube
D Fan Low Energy consumption fan to maximize air flow and low noise
 
Order No. PJO-2016SHSL08145 Product name Dry Cooler Model SHSL-D4-362-6X910F1 Order quantity 1 Gist: JB/T  7659.5-1995
Inspection item    Processing quality                                                                        Processing quality Air pressure test Insulation resistance Electric strength Whole set of products Nameplate and factory file Determine
Item number COIL Length
L≤1000(±2mm)
L>1000(±4mm)
COIL Diagonal
D≤1000(±3mm)
D>1000(±5mm)
Fin pattern Fin: conform to the requirements, no burr, no Rip, no pour, no dew copper, no wrinkles, no burning out.
 
Sheet metal: no scratches and deformation, surface should be clean, smooth, colours and luster is consistent, uniform coating.
 
With ≥1.15 times design pressure to test, no leakage and deformation. Design value: 2.5MPa
 
Electric parts to ground ,to the charged metal parts of the insulation resistance(cold)  2MΩ
 
1800V voltage,keep one minute, no puncture ,no flashover
 
Inlet and outlet connectors;flange ,fan,electric heating tube bracket,valves and so on.
 
content is complete,same with the good, factory file is complete, the specification is correct
2016D08145-001 3300/3303
3300/3304
 3672/3675
3675/3675
Aluminum fin 0.115mm
,2.2mm/ Ripple
Accord Accord 10min/2.5MPa
 
NO NO Accord Accord Qualified
   

Site assessment
Selected installation site must meet the following requirements:
  1. Level Ground;
  2. Ground or Floor strength able to support the wedight of equipment;
  3. no obstructions at air outlet.
  4. Upon confirming above conditions, take the following installation steps. Forklift or lifting product out of wooden pallets, loosen transport screw at stand and tighten after raising the screws to same horizontal plane as product. After moving product to the predetermined location, bolt tightly with large washer and spring washer.
 

Warning
  1. Minimize bias and ensure the level of the product during installation.
  2. Ensure tubes level and no loosen parts in dry cooler
  3. During installation, avoid weight of pipeline on the dry coolers.  
 
  1.  Wiring
  2. Power requirements:       
  3. Axial Fan power wiring: Axial fans are often using one phase or 3 phase motor. The 3 phase motor has two configuration, Y-shape and Shape
  4. Fan motor should have reliable power supply equipped with over voltage, under voltage and over current protection. Each fan is equipped with current protection settings. Internal thermal protection devise should be connected to the control lines to prevent damage to the motor due to over voltage, under voltage, lack of phase, contact failure. Motor wiring shall be installed according to the requirements when using two-speed motor.
 
warning
 
  1. Motor overcurrent protection and built in thermal protection settings must be connected.
  2. Electrical connections must be completed by qualified professionals
  3. Ensure wiring are correct and accurate to prevent motor failure
 
Electrical Installation
 
Warning
 
  1. Equipment installation must be done by qualified personnel
  2. Ensure all electrical circuits are installed in accordance GB 8877-88(household appliances installation, use, maintenance and safety requirements) or any other local regulations
  3. Equipment shall be safely grounded with resistance less than 2Ω
  4. Ensure all fan connecting cables are according to required standards of fan manufacturers.
 
Equipment commissioning
4.1  power on check
Check to ensure all requirements above are met. All requirements is to be met before trial run. Ensure all accessories are installed securely before powering on.
 
4.2  Power supply check
Ensure voltage and power supply matches name plate by measuring equipment and is safely grounded with less than 2ohm before power up.
 
4.3  Trial Operation
Ensure each fan is tighten and is not obstructed prior to commissioning. Rotation of the motor must be accordance with the factory specification. Ensure no jamming and free rotation to fan and motor. 

Photos show:
Industrial Dry Cooler V Shapeddry Coolers
Industrial Dry Cooler V Shapeddry Coolers
Industrial Dry Cooler V Shapeddry Coolers
Industrial Dry Cooler V Shapeddry Coolers
Industrial Dry Cooler V Shapeddry Coolers
Industrial Dry Cooler V Shapeddry Coolers



 

 

Sorgunuzu doğrudan bu sağlayıcıya gönderin

*İtibaren:
*Şuradan:
*Mesaj:

Lütfen 20 ila 4000 karakter arasında girin.

Aradığınız şey bu değil? Satın Alma talebini Şimdi Yayınla

Kategoriye Göre Benzer Ürünleri Bulun

Tedarikçi Ana Sayfası Ürünler Kuru soğutucu Industrial Dry Cooler V Shapeddry Coolers

Bunları Da Beğenebilirsiniz

Tedarikçi ile İletişime Geçin

Elmas Üye Fiyat 2010

Doğrulanmış işletme lisanslarına sahip tedarikçiler

Üretici/Fabrika
Yönetim Sistemi Sertifikasyonu
ISO 9001
OEM (Orijinal Malzeme Üreticisi)/ODM (Orijinal Dizayn Üreticisi) Kullanılabilirliği
Yes