• Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function
  • Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function
  • Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function
  • Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function
  • Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function
  • Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function

Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function

Tip: Fire Alarm
Hırsızlık Önleme Alarm Sistemi yaklaşımı: Etkin
Hırsızlık Önleme Alarm Sistemi Türü: Duman Alarmları
Hırsızlık Önleme Alarm Sistemi - Geniş: Tel Alarm Dedektörleri
Hırsızlık Önleme Alarm Sistemi Mesafesi: Güç Dedektörü
Duman Dedektörü Türleri: Fotoelektrik Duman Stili

Tedarikçi ile İletişime Geçin

Elmas Üye Fiyat 2013

Doğrulanmış işletme lisanslarına sahip tedarikçiler

Üretici/Fabrika, Ticari Şirket

Temel bilgiler.

Hayır. Modeli.
AW-CFP2166
Kızılötesi Sensör Prob Tipi
Eğim Sensörü
Kızılötesi sensörün Takılması
Tavan
Yanıcı Gaz Dedektörü Modeli
YOK-300
öğe
algılama kontrol paneli
bölgeler
1-32
güç kaynağı
110 v ac/240 v ac
pil
12 v2ah * 2
yangın rölesi çıkışı
nc ve no
röle çıkışı arızası
nc ve no
siren çıkışı
2 devre
anahtarlık portu
shenzhen
teslimat süresi
15 gün
ödeme
t/t, batı rakoru
Taşıma Paketi
EPE Inside, Carton Outside
Teknik Özelikler
CE
Ticari Marka
Asenware
Menşei
Guangdong, China
Üretim Kapasitesi
10000PCS/Year

Ürün Açıklaması

1-32 zone conventional fire detection control panel

Introduction:

The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function



1 AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2 It is modularized design, the panel can expend from 1 zone to 32 zones easily.
3 It has 2 level control mode by a lock
4 It has 24VDC and 5VDC power supply output.
5 It has FIRE and FAULT signal output.
6 It has 2 general sounders output.
7 Each zone has 1 circuit detectors input.
8 Each zone can be disable by a button.
9 It has RESET button to reset the panel.
10 It has SILENCE button to stop BUZZER and SOUNDERS.
11 It has EVACUATE button to start a manual fire alarm immediately.
12 It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13 It has an optional GSM module for fire alarm by SMS.
14 It is economic, user-friendly and easy maintenance.
Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function

Parameters:
ITEM 1Zone panel 2Zone panel 4-8 Zone panel 12-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-8 AW-CFP2166-12-32
Power specification
 
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC
Main supply monitor for fault Yes
Battery protection for low voltage Yes
Batteries (default configuration) 12V2AH*2
Detector circuit specification
 
Number of circuit 1 2 4-16 4-32
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Line fault monitor for detector removal Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor
End of Line device 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Detector continuity diodes Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)
Call point resistor value 470 to 680 Ω, 0.225 or 0.5 watt
Maximum number of smoke/heat detectors per zone 20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.
Maximum number of manual call points per zone No limit
Sounder circuit specification
 
Number of general circuits 2
End of line resistor value 6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)
Line fault monitor for open circuit Yes
Line fault monitor for short circuit Yes
Outputs fused AT 400mA
Maximum number of bells @ 20mA of each sounder output 20
Fuses
 
Battery fuse 1.5A F 20mm
Sounder outputs 500mA F 20mm
Fire and fault output
 
Output type NC and NO relay
Maximum current 100mA
Connection block
 
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Size and weight
 

 
Dimensions(mm) 272*200*70mm 320*231*90mm 395X502X124 362X565X124
Weight (without batteries) 4kg 5kg 7kg 8kg
Weight (with batteries) 5.8kg 6.8kg 9.6kg 12.5kg

Show board for conventional fire alarm system

Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function
Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function

Company
Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function



Lpcb Ce Approved Conventional Fire Alarm Control Panel with GSM Function



Contact us

Swing Cao
 
 
 
 
 
 

 
 
 

Sorgunuzu doğrudan bu sağlayıcıya gönderin

*İtibaren:
*Şuradan:
*Mesaj:

Lütfen 20 ila 4000 karakter arasında girin.

Aradığınız şey bu değil? Satın Alma talebini Şimdi Yayınla